Skip to content

Consolidate input argument combination checking for EK80 data #1745

Description

@leewujung

Right now we have 2 places that checks the combination of input argument for compute_Sv/Sp in terms of encode_mode and waveform_mode.

Here:

# TODO: consolidate the below block with simrad.py::check_input_args_combination()
# Check on waveform_mode, encode_mode inputs, and assumption on single filter time
if echodata.sonar_model == "EK80":
if waveform_mode is None or encode_mode is None:
raise ValueError("waveform_mode and encode_mode must be specified for EK80 calibration")
check_input_args_combination(waveform_mode=waveform_mode, encode_mode=encode_mode)
elif echodata.sonar_model in ("EK60", "AZFP", "AZFP6"):
if waveform_mode is not None and waveform_mode != "CW":
logger.warning(
"This sonar model transmits only narrowband signals (waveform_mode='CW'). "
"Calibration will be in CW mode",
)
if encode_mode is not None and encode_mode != "power":
logger.warning(
"This sonar model only record data as power or power/angle samples "
"(encode_mode='power'). Calibration will be done on the power samples.",
)

and in the function check_input_args_combination here:

def check_input_args_combination(
waveform_mode: str, encode_mode: str, pulse_compression: bool = None
) -> None:
"""
Checks that the ``waveform_mode`` and ``encode_mode`` have
the correct values and that the combination of input arguments are valid, without
considering the actual data.
Parameters
----------
waveform_mode: str
Type of transmit waveform
encode_mode: str
Type of encoded return echo data
pulse_compression: bool
States whether pulse compression should be used
"""
if waveform_mode not in ["CW", "BB"]:
raise ValueError("The input waveform_mode must be either 'CW' or 'BB'!")
if encode_mode not in ["complex", "power"]:
raise ValueError("The input encode_mode must be either 'complex' or 'power'!")
# BB has complex data only, but CW can have complex or power data
if (waveform_mode == "BB") and (encode_mode == "power"):
raise ValueError(
"Data from broadband ('BB') transmission must be recorded as complex samples"
)
# make sure that we have BB and complex inputs, if pulse compression is selected
if pulse_compression is not None:
if pulse_compression and ((waveform_mode != "BB") or (encode_mode != "complex")):
raise RuntimeError(
"Pulse compression can only be used with "
"waveform_mode='BB' and encode_mode='complex'"
)

The checks these code blocks perform are different, since one also deals with different sonar_models, but I think it would be cleaner to just have 1 function in the calibration subpackage to do this (check_input_args_combination shouldn't be in echodata/simrad.py).